Welcome to Dhananjay Technical Services ("DTS", "the Firm", "we", or "us"). By accessing our website (dts-journey.vercel.app), contracting our statutory inspection services, submitting purchase orders, or receiving safety compliance certifications issued by our certified Competent Persons and Chartered Engineers, you ("Client", "User", "Plant Operator") agree to be bound by these Terms & Conditions.
All physical inspections, testing protocols, non-destructive evaluations (NDT), hydro-tests, and certificate issuance strictly conform to the Factories Act 1948, Madhya Pradesh Factories Rules 1962, Gas Cylinders Rules 2016, SMPV (Unfired) Rules 2016, and codes established by the Petroleum and Explosives Safety Organization (PESO) and The Institution of Engineers (India).
1. Scope of Professional Services
DTS provides technical and statutory inspection services across the following primary domains:
- Statutory Inspections (Factories Act 1948): Examination and certification of lifting machines, chains, ropes, cranes, tackles (Form 9 & 10), and pressure plants/vessels (Form 8 & 11).
- PESO Authorized Hydro Testing: Periodic hydrostatic stretch testing, internal inspection, ultrasonic flaw detection, and tare weight verification of CNG, CBG, Industrial gas, and cascading cylinders.
- Chartered Engineer Certifications: Technical audits, machinery import valuation certificates, customs clearances, and factory building structural stability certifications.
- Non-Destructive Testing (NDT): Ultrasonic thickness gauging, magnetic particle testing, dye penetrant inspection, and visual weld evaluations.
2. Client Site Preparedness & Safety Obligations
To ensure valid, rigorous, and hazard-free inspections, the client agrees to:
- Safe Access: Provide DTS engineers with safe, unobstructed access, adequate scaffolding/platforms complying with OSHA and Indian safety standards, and clear illumination to all equipment scheduled for inspection.
- Depressurization & Isolation: Ensure all pressure vessels, lines, and autoclaves are completely depressurized, vented, isolated from hazardous gas/chemical supplies (lockout/tagout), and cooled to ambient temperatures prior to internal examination.
- Documentation & Historical Records: Furnish historical maintenance logs, prior inspection certificates, manufacturer data reports (MDR), and safety relief valve calibration records upon arrival of the inspection team.
- Authorized Escort: Assign a qualified site safety officer or plant maintenance engineer to accompany the DTS inspection team throughout the testing procedure.
3. Certificate Issuance & Statutory Authority
Certificates issued by DTS Competent Persons and Chartered Engineers reflect the empirical physical and structural condition of inspected equipment strictly at the date and time of test completion.
- Integrity of Findings: DTS maintains uncompromising technical independence. Certificates will only be issued when equipment unequivocally meets the statutory safety thresholds dictated by Indian law.
- Refusal of Certification: If equipment exhibits severe wall thinning, fatigue cracking, improper safety relief valves, or structural compromise, DTS reserves the statutory obligation to issue a rejection report or corrective notice.
- Unauthorized Alterations: Any unapproved welding, physical modification, operating parameter increase, or structural alteration performed on certified equipment immediately voids the DTS certificate.
4. Quotations, Invoicing & Payment Terms
Formal quotation documents provided through our portal or written proposals remain valid for thirty (30) calendar days from the date of issue. Commercial terms include:
- Payment terms are strictly within thirty (30) days of invoice date unless an enterprise Master Service Agreement (MSA) stipulates alternative terms.
- Goods & Services Tax (GST) is charged at prevailing statutory rates under applicable Indian tax legislation.
- Official certificates and test records will be dispatched upon receipt of agreed advance or milestone payments.
5. Limitation of Liability
DTS performs all statutory examinations with professional diligence adhering to accepted engineering standards. However, in no event shall DTS, its directors, partners, or certified inspectors be held liable for:
- Equipment failure or industrial accidents resulting from subsequent operator error, lack of routine plant maintenance, unrecorded operating pressure spikes, or willful neglect following inspection.
- Consequential, indirect, special, or liquidated damages, including factory downtime, loss of production output, or commercial business disruption.
- The total aggregate liability of DTS for any proven claim arising out of a specific inspection shall not exceed the professional inspection fee received by DTS for that individual engagement.
6. Intellectual Property & Website Use
All content published on this website—including regulatory guides, safety articles, design tokens, logos, and illustrations—is the exclusive intellectual property of Dhananjay Technical Services. Content may not be copied, reproduced, scraped, or republished without prior written authorization.
7. Force Majeure
Neither party shall be liable for delays or non-performance caused by events beyond reasonable control, including acts of God, industrial gas shortages, regional power outages, severe weather, governmental lockdowns, or regulatory moratoriums issued by DISH or PESO.
8. Governing Law & Jurisdiction
These Terms & Conditions and any commercial engagements entered into with DTS shall be governed by and construed in accordance with the laws of India. Any legal dispute, arbitration, or statutory claim arising under these terms shall be subject to the exclusive jurisdiction of the competent courts in Jabalpur / Indore, Madhya Pradesh.
9. Contact & Statutory Inquiries
For questions concerning our terms of engagement or to verify the authenticity of an inspection certificate, please reach out directly:
Corporate & Industrial Inspection Office
Address: DTS CNG Cylinder Testing Station, Madhya Pradesh, India
Phone: +91-8770874736 / +91-7000081554
Email: dtsdhananjay1969@gmail.com